絞り込み

17712

広告

伊方原発3号機 定期検査 約半年ぶりに再開 トラブル相次ぎ中断 (NHK)

トラブルが相次いだことをうけて中断していた、愛媛県伊方町にある伊方原発3号機の定期検査について、四国電力は5日、およそ半年ぶりに再開しました。 伊方原発3号機は...

  1. 形成まもない銀河を現在の宇宙の中で発見 ...
  2. [医学] 間もなく増えるであろう小児の急...
  3. 台所のみ、売り上げ月500万円 レストラ...
  4. 埼玉県もTikTok利用停止 知事「情報...

ニュース一覧

Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.

著者 Huang CC , Fu JY , Hu HC , Kao KC , Chen NH , Hsieh MJ , Tsai YH
Crit Care Med.2008 Oct ; 36(10):2810-6.
この記事をPubMed上で見るPubMedで表示
この記事をGoogle翻訳上で見る Google翻訳で開く

Division of Pulmonary and Critical Care Medicine, Chang Gung Memorial Hospital, Gweishan, Taoyuan, Taiwan.

スターを付ける スターを付ける     (167view , 0users)

Full Text Sources

Medical

OBJECTIVE: Dynamic preload indicators with pulse pressure variation and stroke volume variation are superior to static indicators for predicting fluid responsiveness in mechanically ventilated patients. However, they are influenced by tidal volume and the level of positive end-expiratory pressure. The present study was designed to evaluate the clinical applicability of pulse pressure variation and stroke volume variation in predicting fluid responsiveness on acute respiratory distress syndrome patients ventilated with protective strategy (low tidal volume and high positive end-expiratory pressure). DESIGN: Prospective, observational study. SETTING: A 20-bed medical intensive care unit of a tertiary medical center. PATIENTS: Twenty-two sedated and paralyzed early acute respiratory distress syndrome patients. INTERVENTIONS: After being enrolled, central venous pressure, pulmonary capillary wedge pressure, and cardiac output index were obtained from a pulmonary artery catheter (OptiQ SvO2/CCO catheter), and intrathoracic blood volume, global end-diastolic volume, stroke volume variation, and pulse pressure variation were recorded from a PiCCOplus monitor. The whole set of hemodynamic measurements was performed before and after volume expansion with 500 mL hydroxyethyl starch (10% pentastarch 200/0.5). MEASUREMENTS AND MAIN RESULTS: Cardiac output index, central venous pressure, pulmonary capillary wedge pressure, global end-diastolic volume, and intrathoracic blood volume significantly increased, and pulse pressure variation and stroke volume variation significantly decreased after volume expansion. Baseline pulse pressure variation significantly correlated with volume expansion-induced absolute changes (r = .62), or percent changes in cardiac output index (r = .75) after volume expansion. The area under the receiver operating characteristic curve was the highest for pulse pressure variation (area under the receiver operating characteristic curve = 0.768) than other indicators. The threshold value for baseline pulse pressure variation greater than 11.8% predicted a significant positive response to volume expansion with a sensitivity of 68% and a specificity of 100%. CONCLUSIONS: Baseline pulse pressure variation accurately predicted the fluid responsiveness in early acute respiratory distress syndrome patients. Roughly, a baseline pulse pressure variation greater than the threshold value of 12% is associated with a significant increase in cardiac output index after the end of volume expansion.
PMID: 18766099 [PubMed - indexed for MEDLINE]
印刷用ページを開く Endnote用テキストダウンロード